cdc Questions
4
There's no shortage of topics covering this function and error "An insufficient number of arguments were supplied for the procedure or function cdc.fn_cdc_get_all_changes". I've checked most of the...
Warner asked 16/7, 2014 at 10:59
2
I want to connect an USB CDC Device (an FTDI chip or a CD2010 or a custom made) to my Galaxy A12 (Android SDK 30) using the following code (AndroidStudio Chipmunk):
public class MainActivity extend...
5
Solved
Seemingly valid code for querying the latest tracked changes in the table Fields:
DECLARE @Begin_LSN BINARY(10), @End_LSN BINARY(10)
SET @Begin_LSN = sys.fn_cdc_get_min_lsn('Fields')
SET @End_LSN ...
Tremolant asked 30/4, 2013 at 12:2
6
I am having problems setting up change data capture on a SQL Server 2012 instance. Whenever I attempt to enable CDC on a table I get the following error:
Msg 22832, Level 16, State 1, Procedure ...
Charlacharlady asked 13/3, 2015 at 13:38
4
Solved
I dropped a table before disabling CDC for that. Now when I recreated the table and tried enabling CDC it says that capture instance already exists. I can use a different Capture Instance name but ...
Concinnate asked 3/12, 2009 at 8:2
3
Solved
What are the differences between JDBC Connector and Debezium SQL Server CDC Connector (or any other relational database connector) and when should I choose one over another, searching for a solutio...
Vancouver asked 29/3, 2020 at 0:48
4
Solved
This is a follow-up to my previous question, Need to write driver for USB peripheral device?
Background
I'm working on designing a USB peripheral using an STM32 microcontroller (bare metal / no O...
2
Solved
I am looking for a snippet of code that will cause a stream to empty, essentially resetting it. Here is the use case. We use streams to track changes for type 2 dimension tables into a data mart. T...
Dustpan asked 11/6, 2020 at 13:10
3
Solved
I've got a compound USB + CDC device I built using a PIC32 microcontroller, and I'm trying to connect to the device and send some data to the CDC data interface endpoint from my Mac.
I know the ci...
Leveille asked 27/11, 2013 at 21:24
4
Solved
What is the meaning of Log Sequence Number? I know that it is of type binary and 10bytes long and it corresponds to the time the transaction happen in DB. But is this a high precision date-time val...
Rida asked 17/7, 2009 at 13:2
3
Solved
I have Change Data Capture (CDC) activated on my MS SQL 2008 database and use the following code to add a new tabel to the data capture:
EXEC sys.sp_cdc_enable_table
@source_schema ='ordering',
@s...
Jecon asked 30/4, 2013 at 10:56
7
Solved
I am using an STM32F105 microcontroller with the STM32_USB-FS-Device_Lib_V3.2.1 USB library and have adapted the VCP example for our purposes (integration with RTOS and serial API).
The problem is...
1
I am trying to connect an scale (Dibal series 400) in Linux (Ubuntu), and I can not succeed. The scale works on Windows after installing a driver to enable a Virtual Com Port, but when I plug in th...
Perverted asked 24/11, 2017 at 21:27
2
I'm using an STM32L151 to communicate with a PC using USB CDC. I used the STM32 HAL libraries to create my project.
I found that the USB sends data in 1 ms intervals, and each time 64 bytes are bei...
6
I asked a question on SOF a week or so ago about auditing SQL data changes. The usual stuff about using triggers came up, there was also the mention of CDC in SQL Server 2008.
I've been trying it...
Slaver asked 15/5, 2009 at 15:18
2
When a new column is added to table that is configured for change data capture (cdc), the capture instance table will not have the new column until cdc is disabled and re-enabled for the source tab...
Apologize asked 16/4, 2010 at 17:6
2
Solved
I have a requirement where I want to enable CDC on newly added columns of table, but I cannot disable CDC and enable it again. Is there any way I can achieve this?
I found a solution where I can c...
Absolve asked 26/7, 2016 at 10:13
0
I was trying to enumerate usb cdc device using pic24fj128gb206.
Device seems to be enumerated properly.
But when I connect my device to Linux PC, I am getting the below warning message from kernel...
3
I am getting this error
"An insufficient number of arguments were supplied for the procedure or function cdc.fn_cdc_get_all_changes_" while trying to execute the following sql query.
use Spatial...
Downhill asked 26/6, 2013 at 6:56
2
Am trying to get the net changes on CDC enabled table by passing Min and Max dates. But is throwing below error.
Msg 313, Level 16, State 3, Line 24
An insufficient number of arguments were suppli...
Infrangible asked 20/3, 2013 at 1:42
2
Solved
1
I'm trying to get some data out of a USB device connected to my Android phone that is on host mode. I'm able to send data to it, but reading fails.
I've looked at several examples and tried all I ...
1
I am enabling Change data capture (CDC) on SQL server 2012 Enterprise edition(11.0.2100.60)
. I am able to enable it on Database level with below SQL, but failed to enable on Table level.
Use Dat...
Terminal asked 31/5, 2014 at 11:52
1
Solved
I have enabled CDC using the following steps:
exec sys.sp_cdc_enable_db;
exec sys.sp_cdc_enable_table
@source_schema = N'dbo',
@source_name = N'table_name',
@role_name = N'CDC_Access',
@supports_...
Habituate asked 19/5, 2014 at 17:49
1
Solved
I'm having trouble with unexpected characters being sent on a USB port with the cdc_acm driver. What makes this all the more perplexing is that the code runs fine on Ubuntu 12.04 (3.2 kernel) but f...
1 Next >