I have a datasnap server with a vcl forms client. From the client, how can I handle if the server has been say shutdown and restarted with existing client connections? This scenario raises a 10053 EIdSocketError exception.
To replicate, I run up both Server and Client, make a call to the server (I use methods exposed via the DataSnap proxy generator) which succeeeds. I then shut down the server (eg Close the application) and restart it. I then attempt to make a call to the server again.
eg: CLIENT call
sm := TsvrPolicySearchClient.Create(datClientDB.SQLConnection1.DBXConnection);
try
ds := sm.SearchPolicyByPolicy(40, WCRef, '', 3);
dspPolicyGroup.DataSet := ds;
if cdsPolicyGroup.Active then
cdsPolicyGroup.Refresh
else
cdsPolicyGroup.Open;
finally
sm.Free;
end;
dspPolicyGroup is a TDataSetProvider and cdsPolicyGroup is a TClientDataSet (I just use it locally to "store" my TDataSet result).
SERVER
function TsvrPolicySearch.SearchPolicyByPolicy(AClientId: Integer; WCRefNum, ClientRef: string; SearchMethod: Integer): TDataSet;
begin
spPolicyByWCRef.Close;
spPolicyByWCRef.ParamByName('p_client').AsInteger := AClientId;
spPolicyByWCRef.ParamByName('p_search_method').AsInteger := SearchMethod;
spPolicyByWCRef.ParamByName('p_wc_refno').AsString := WCRefNum;
spPolicyByWCRef.Open;
Result := spPolicyByWCRef;
end;
I would think this is regularly encountered by people seeing that it's quite easy to replicate. Should I place a "Test Connection" call or something first (such as a method TestConnection) before each call to check for EIdSocketError (and equivalent) and handle? Or is it more a design flaw perhaps?