The problem is that FlameRobin needs to know when a statement ends and the next statement starts. By default it uses the semicolon (;
) for this. However an EXECUTE BLOCK
is essentially a stored procedure that isn't stored in the database, so it contains PSQL code that also uses the semicolon as a statement separator.
The consequence of this is that you get syntax errors because FlameRobin is sending incomplete statements to the server (that is: it is sending a statement after each ;
it encounters).
You need to instruct FlameRobin to use a different statement terminator using SET TERM
. Other Firebird query tools (eg isql) require this as well, but it is not actually part of the syntax of Firebird itself!
So you need to execute your code as:
-- Instruct flamerobin to use # as the terminator
SET TERM #;
EXECUTE BLOCK
AS
DECLARE customerID INT = 1234;
BEGIN
SELECT * FROM customers WHERE customerid = :customerID;
END#
-- Restore terminator to ;
SET TERM ;#
However doing this will still result in an error, because this query is invalid for PSQL: A SELECT
in a PSQL block requires an INTO
clause to map the columns to variables. And to get the values out of the EXECUTE BLOCK
returned to FlameRobin you also need to specify a RETURNS
clause as described in the documentation of EXECUTE BLOCK
:
-- Instruct flamerobin to use # as the terminator
SET TERM #;
EXECUTE BLOCK
RETURNS (col1 INTEGER, col2 VARCHAR(100))
AS
DECLARE customerID INT = 1234;
BEGIN
SELECT col1, col2 FROM customers WHERE customerid = :customerID INTO :col1, :col2;
SUSPEND;
END#
-- Restore terminator to ;
SET TERM ;#
As far as I know the SUSPEND
is technically not required here, but Flamerobin will not fetch the returned row if it isn't included.
However the above will not work if the select produces multiple rows. For that you need to use FOR SELECT ... DO
combined with a SUSPEND
:
-- Instruct flamerobin to use # as the terminator
SET TERM #;
EXECUTE BLOCK
RETURNS (col1 INTEGER, col2 VARCHAR(100))
AS
DECLARE customerID INT = 1234;
BEGIN
FOR SELECT col1, col2 FROM customers WHERE customerid = :customerID INTO :col1, :col2
DO
SUSPEND;
END#
-- Restore terminator to ;
SET TERM ;#
The SUSPEND
here returns the row and waits until the caller has fetched that row and then continues with the FOR
loop. This way it will iterate over the results.
IMHO this too much effort for parameterization. You might want to consider simply not parametrizing when you use FlameRobin, or use a tool that supports asking for parameter values for the normal parameter placeholders of Firebird (but to be honest I am not sure if there are any).